Gasproof Membranes

Gasproof membranes

Installing Gasproof Membranes: Ensuring Protection and Mitigation

Gasproof membranes play a crucial role in safeguarding structures against harmful gases such as radon and volatile organic compounds (VOCs). With adherence to standards such as BS8102:2022 for waterproofing and BS8485 for gas protection, Cannon Clarke offers expertise in designing and deploying installations that provide robust defence against these hazards.

Understanding Gasproof Membranes:

Gasproof membranes are specialised barriers designed to prevent the ingress of gases, including radon and VOCs, into buildings. Radon, a radioactive gas derived from the decay of uranium in soil and rock, can accumulate indoors and pose serious health risks, including an increased risk of lung cancer. VOCs are organic chemicals that can vaporise and release into the air, potentially causing adverse health effects such as respiratory irritation and exacerbation of existing conditions.

The Role of Standards:

Adhering to standards such as BS8102:2022 and BS8485 is essential for ensuring the effectiveness and durability of gasproof membrane installations. BS8102:2022 provides guidance on waterproofing below-ground structures, including recommendations for the selection and installation of membranes to protect against water ingress. BS8485 specifically addresses the protection of buildings from hazardous ground gases, outlining measures to mitigate risks associated with radon and VOCs.

How Cannon Clarke Can Help?

Cannon Clarke offers comprehensive solutions for designing and deploying gasproof membranes tailored to the unique requirements of each project. Our team of experts utilises industry-leading techniques and materials to deliver effective protection against radon and VOCs.

Services Offered:

Site Assessment: We conduct thorough assessments to identify potential risks and determine the most appropriate membrane system for the site, considering factors such as soil composition, groundwater levels, and building design.

Design and Specification: Our experienced engineers develop detailed designs and specifications in accordance with BS8102:2022 and BS8485, ensuring compliance with regulatory requirements and best practices in gas protection.

Installation: With extensive experience in membrane installation, our skilled technicians ensure precise and efficient deployment, utilising advanced techniques to achieve a seamless and durable barrier against gas ingress.

Verification of our Works: Having gasproof membrane installations checked by a third-party verification standard is of paramount importance for several reasons:

Quality Assurance: Third-party verification ensures that the installation meets established standards and regulations. This independent assessment helps to confirm that the gasproof membrane has been installed correctly and is functioning as intended.

Compliance: Many regulatory bodies and building codes require verification of gas protection measures, including gasproof membranes. Compliance with these requirements is essential to avoid potential legal issues and ensure the safety and integrity of the structure.

Risk Mitigation: Gas ingress, particularly from substances like radon and VOCs, can pose significant health and safety risks to building occupants. Third-party verification helps to mitigate these risks by providing assurance that the gasproof membrane is effectively preventing the entry of harmful gases into the building.

Long-Term Performance: Gasproof membrane installations are intended to provide long-term protection against gas ingress. Third-party verification can help to identify any potential issues or deficiencies early on, allowing for corrective action to be taken before problems escalate and ensuring the continued effectiveness of the membrane over time.

Confidence and Trust: Third-party verification instils confidence in building owners, occupants, and stakeholders that the gasproof membrane installation has been carried out to the highest standards of quality and integrity. It provides an objective assessment of the installation’s performance, fostering trust in the reliability and safety of the building.

Overall, third-party verification of gasproof membrane installations is essential for ensuring compliance, mitigating risks, and maintaining the long-term effectiveness of gas protection measures. It provides peace of mind for all involved parties and contributes to the overall safety and sustainability of the built environment.

Conclusion:

Gasproof membranes are essential components of building construction, providing vital protection against radon and VOCs. By adhering to industry standards and leveraging expertise in design and installation, Cannon Clarke delivers comprehensive solutions that mitigate risks and safeguard indoor environments. Contact us today to learn more about our services and how we can help protect your building against harmful gases.

Trusted Across Bath, Bristol & the South West

Cannon Clarke delivers domestic and commercial structural waterproofing across:

  • Bath — heritage properties, basement conversions, retaining walls
  • Bristol — modern developments, commercial units, residential refurbishments
  • Somerset & Wiltshire — rural properties, cellars, below‑ground extensions

Trusted by:

  • Surveyors
  • Insurers
  • Property managers
  • Homeowners across the South West

Our reputation is built on technical accuracy, reliability and long‑term results.

 

Case Study Snapshots

Bath — Basement Conversion

Installed a full cavity drainage system with sump and pump, resolving long‑term damp issues and enabling a habitable living space.

Bristol — Commercial Unit

Applied cementitious waterproofing to retaining walls experiencing hydrostatic pressure, preventing water ingress during peak rainfall.

Somerset — Heritage Property

Designed a non‑intrusive waterproofing solution compatible with historic masonry and conservation requirements.

Compliance & Standards

Our waterproofing systems meet:

  • BS 8102:2022 — Code of practice for protection of below‑ground structures where applicable 
  • Manufacturer installation standards
  • Insurance‑backed guarantee requirements

All work is carried out by our employed trained specialists with extensive experience in below‑ground protection.

FAQs

What causes basement leaks?

Basement leaks are typically caused by hydrostatic pressure, poor drainage, failed membranes or structural cracks.

Do you follow BS 8102?

Yes. Where Applicable all waterproofing systems are designed and installed in accordance with BS 8102:2022.

Can waterproofing be added to existing basements?

Absolutely. We regularly retrofit waterproofing systems to older properties and heritage buildings.

How long does installation take?

Most projects take between  5–10 days depending on size and complexity. (larger projects will take longer.

Do you offer guarantees?

Yes. We provide manufacturer-backed and insurance-backed guarantees where applicable.

More information?

For reliable structural waterproofing, call Cannon Clarke or book a professional survey. We’ll assess your property, explain your options and provide a clear, compliant plan. 

Our Process

Survey

We start by conducting a thorough survey of the space you want inspected. There's usually a fee for our initial consultation.

01

Scoping discussion

We collaborate with you to marry your objectives with our findings from the survey. We’ll discuss how you want to use the space when it’s finished and the best way of achieving your vision.

02

Design

Once we have the physical specifications, and your input on your requirements, we’ll design a system that works for you.

03

Approval

We’ll send you a specification, together with a report which explains the technical aspects. We’re happy to chat through this with you and make any changes you’ve identified.

04

Work begins

With an approved plan in place, we’ll get to work on the date we’ve agreed between us.

05

get in touch today

Contact us to discuss Gasproof membranes

CONTACT US TO BOOK A SITE SURVEY 

11 + 10 =